2005 - 2014 = EXPERIMENTATION RESULTS OF "ENERGYMAIS" BURNER
Ing. Roberto Gaietta, CO.M.I.GE. s.r.l.- PAVIA - comige@comige.it - www.comige.it - www.energymais.info
After many years of tests and improvements of the system "ENERGYMAIS", we can state that the results were exciting:
- ABATMENT OF THE FUEL COST FOR DRYINGBy burning exclusilely seconds produced by the drying process
- SECONDS INCINERATION TO 2% BOTTOM ASHES
- ZERO COST OF SECONDS DISPOSAL
- SECONDS VALORIZATION TO A VALUE MUCH MORE THAN GOOD CEREALS GRAINS
- ZERO COST OF TRADITIONAL FUELS FOR DRYING PROCESS (EU 20-20-20 program)
- ZERO CO2 EMISSIONS INTO ATMOSFERE (KYOTO)
Economic results of Energymais during the 2014 drying season at the Barley Drying Center HIGHLAND GRAIN Ltd. - Inverness - SCOTLAND
HIGHLAND GRAIN Ltd. - Inverness - 2014 season | ||
---|---|---|
dried barley | ton | 7.660 |
buried seconds | ton | 257 |
burned oil x start | lt | 10.305 |
oil cost | £/lt | 0,585 |
dried tons/24h | ton/24h | 192 |
total days (24h) | days | 40 |
Cal. Value seconds | kCal/kg | 3.540 |
kCal from seconds | kCal | 909.780.000 |
Cal. Value oil | kCal/lt | 8.500 |
kCal from oil | kCal | 87.592.500 |
total kCal (seconds + oil) | kCal | 997.372.500 |
total oil needed | lt | 117.338 |
total oil needed | £ | 68.642,70 |
oil cost x start | £ | 6.028,43 |
OIL SAVED | lt | 107.033 |
OIL SAVED | £ | 62.614,27 |
OIL SAVED (£/€ 1,27) | € | 79.520,12 |
CO2 EMISSIONS SAVED | ton | 284 |